HEL - Better Chemistry - Faster
 
Product Quick Links:
People:products Periodic Table
YOU ARE HERE:   home : reactor systems : safety, calorimetry, & hazards
Print
   Reactor Systems:
PolyBLOCK:Reactor Blocks
High-throughput Screening
Parallel Process Optimisation
Particle Science & Crystallisation Investigations
Scale-Up: Bench & Pilot Scale
High Pressure Reactors
Automation Tools
Safety, Calorimetry, & Hazards
Bio Reactors
Publications


Safety, Calorimetry, and Process Hazards



Overview TSu Thermal Screening Unit Simular Reaction Calorimeter On-Line Calorimetry Phitec I Adiabatic Calorimetry Battery Testing Phitec II - Phi Factor
Safety and scale-up tools for quick and reliable hazards data...

TSu (Thermal Screening)
  • Small, compact, and simple thermal screening.
  • Designed to be used in the first step of hazards analysis.
  • The TSu provides calorimetry and pressure data, making it superior to DSC/DTA.
  • Thermo-kinetic data also available
  • Thermal stability testing at sub ambient temperature

Further information...
Request literature...
 


Simular (Reaction Calorimetry)
  • Obtain data for safe and efficient scale-up.
  • The Simular is available with many different options.
  • The flexibility allows the user to closely simulate plant conditions.
  • On-line Calorimetry is now accessible to development chemists on ANY stirred reactor without special features or adaptations.


Further information...
Request literature...
 

Phitec I (Classic Adiabatic Reaction Calorimetry)
  • Compact system, small footprint
  • Custom battery testing version also available
  • Update of classic ARC* from Dow
  • Sensitive exotherm detection, with automatic on-line calibration
  • Sample agitation available as standard
  • Custom test cell design
  • Temperature of sample DIRECTLY monitored
  • Thermal stability testing at sub-ambient temperature
  • Battery testing version also available


*ARC is now a registered trademark of Thermal Hazard Technology/Netzsch Asset Management LLC.
Further information...
Request literature...
 

Phitec II (Low and High phi-factor Adiabatic Calorimetry)
  • Adiabatic calorimeter for simulating runaway exothermic reactions in a large-scale chemical reactors.
  • Extremely sensitive exotherm detection
  • The low phi-factor provides directly scalable data
  • Vent sizing for DIERS calculations
  • Phitec II can be used for thermal screening (ramp tests), high -factor adiabatic testing, low -factor adiabatic testing


Further information...
Request literature...
 


Phi-TEC BTC
  • Battery safety testing calorimeter
  • Allows batteries up to 35cm x 35cm to be tested
  • Stability testing
  • Testing to destruction

Further information...
Request literature...
 







Product Info